With decades of experience and expertise in G5 HFPS of ESP (5th generation high frequency power source of electrostatic precipitator), Chindow’s design team makes greatest effort to achieve the ease of SKD (semi-know-down) assembly process so that Chindow’s foreign partners can assemble G5 HFPS of ESP easily in their own workshop with key parts and detailed training to be supplied by Chindow and with the enclosure (cabinet) & other accessory components to be made or sourced locally by the partners.
G4 HFPS of ESP
60~120kV 200~2600mA
Chindow is the only one company in the world that manufactures both G5 HFPS and G4 HFPS of ESP
G5 HFPS of ESP
60~120kV 400~3000mA
Chindow G5 HFPS of ESP
boasts its DSP-controlled IGBT bridge working as rectifier for DC link capacitor, which contributes to all the advantages of G5 HFPS of ESP like ideal HV out waveform and consequent outstanding dust collecting performance, higher power factor, higher efficiency and lower THD (total harmonic distortion)
Chindow G4 HFPS of ESP is of the same topology and performance as the HFPS designed by major global players characterized by its diode as rectifier bridge for DC link capacitors
Parameter | G5 HFPS of Chindow | G4 HFPS (SMPS) of other brand | Remarks |
Input voltage for DC Link capacitor | 1300V DC | 540VDC | |
Power factor (full load) | 0.99 | 0.94 | |
Efficiency | 94% | 92% | |
THDi (full load) | 3.2% | 27.8% | |
Input kVA | 160KVA | 177kVA | Take 150kW DC output for example |
Extra cost for harmonic filter | No | Yes |
Chindow G5 HFPS of ESP
boasts its DSP-controlled IGBT rectifier bridge working as rectifier for DC link capacitor, which contributes to all the advantages of G5 HFPS of ESP like ideal HV out waveform and consequent outstanding dust collecting performance, higher power factor, higher efficiency and lower THD (total harmonic distortion)
Single phase 50Hz TR & CC (transformer rectifier & control cabinet) is characterized by its bulky transformer and separate control cabinet with 3 times the weight of G5 HFPS or G4 HFPS
Parameter comparison between G5 HFPS and single phase 50Hz TR & CC
Item | Single phase 50Hz TR & CC | G5 HFPS | Remarks |
Frequency | 50Hz/300Hz | 30k Hz | 50Hz for single phase, 300Hz for 3 phase |
Power factor | 0.65 | 0.99 | |
THDi | 27% | 3.2% | |
Efficiency | 90% | 93% | |
kVA consumption | 256kVA | 162KVA | Take 150kW DC output for example |
Total weight | 2300kg | 850kg | Take 150kW DC output for example |
Transformer weight | 1600kg | 130kg | Take 150kW DC output for example |
Transformer oil volume | 1300L | 110L | Take 150kW DC output for example |
Sparking current | 100 | 1 | times ofthe rated current |
Transformcer oil maintenance cyle | to be filtered every 2 years | minimal 10 years | as result of sparking current |
|
|